Precor Treadmills 932i Service Manual Page 42

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 41
C932, C932i, C934, C936i Treadmilll
Page 42
Procedure 6.8 - Replacing the Line Cord
1. Set the treadmill circuit breaker in the “off” position and unplug the treadmill’s line cord from
the AC outlet.
2. Remove the sheet metal screw that is approximately in the center of the treadmill dress
panel. Remove the four bolts that fasten the treadmill dress panel to the treadmill.
3. Remove the nut that fastens the line cord’s ground wire (green/yellow wire) to the dress
panel.
4. Disconnect the line cord’s brown wire from the circuit breaker. Disconnect the line cord’s
blue wire from the line filter.
5. Remove the line cord’s strain relief mounting nut and remove the line cord.
6. Remove the mounting nut from the replacement line cord and feed the replacement line
cord through the treadmill dress panel. Fasten the line cord to the circuit breaker mounting
plate with the nut removed in the previous step.
7. Connect the line cord’s brown wire to the circuit breaker per Diagram 6.5.
8. Connect the line cord’s blue wire to the line filter per Diagram 6.5.
9. Connect the line cord’s ground wire (green/yellow wire) to the treadmill dress panel with the
hardware removed in step 3.
10. Set the dress panel in its mounting position, hand start the four mounting bolts and the sheet
metal screw removed in step 2. Torque the four dress panel bolts to 120 inch pounds.
Torque the sheet metal screw to 90 inch pounds.
11. Replace the hood per Procedure 6.11.
12. Check treadmill operation per Section 3.
Page view 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 48 49

Comments to this Manuals

No comments