Precor EFX546 Service Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 66
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
C546 Self Powered Elliptical Fitness Crosstrainer
Page 2
Section One - Things You Should Know
Right, Left, Front, and Back Conventions
In this manual, right, left, front, and back are from the perspective of a user standing on the C546,
facing the display enclosure.
General System Information
The ramp operating system has a battery monitoring system. If the battery voltage falls
below 11 Vdc when ramp movement is initiated or the battery voltage falls below 10 Vdc
after ramp movement has been initiated, ramp movement will be stopped and the message
NO RAMP LOW VOLTAGE” will be displayed. Ramp motion will not be enabled until such
time as the battery voltage exceeds the above limits.
The generator performs three functions in the EFX. First, by controlling the amount of
electrical load applied to the generator, the user’s pedalling resistance is controlled.
Second, the generator is used to charge the EFX’s internal battery. Lastly, one of the
generators three phase output windings is monitored to determine when the unit is in use
and when it is idle. This system also determines the stride rate by determining the operating
speed (output frequency) of the monitored generator winding.
Warning and Caution Statements and General Safety Guidelines
Warning statements indicate a particularly dangerous activity. Warning statements you will find in
this manual include:
If the EFX has been in recent use, the load resistors and load resistor mounting bracket may
be extremely hot.
Because this is a self powered unit, it will either be necessary to either equip the unit with
the optional external power supply or have an assistant pedal on the unit while voltage
measurements are being taken. Because of the danger of working on the unit while it is in
motion using the optional external power supply is strongly recommended.
When the unit is used, stairarms are in motion, the generator will operate and produce
potentially hazardous voltages even when the battery is disconnected.
To remove power from the EFX, the optional external power supply (when equipped) must
be disconnected from the wall outlet and the red (positive) lead must be disconnected from
the battery. Always ensure that the EFX external power supply is unplugged from the wall
outlet and the red (positive) lead is removed from the battery when you inspect or adjust the
EFX, or when you isolate, remove, or replace an EFX component.
Page view 1
1 2 3 4 5 6 7 ... 65 66

Comments to this Manuals

No comments