11. Remove the four screws from the rear of the upper display housing. Remove the display
housing front panel from the display housing. Disconnect the upper interconnect cable from
the upper PCA.
12. Disconnect the upper interconnect cable from the mid-point connector. See Diagram 6.2
Diagram 6.2 - Mid-Point Connector
13. External of the upper column, connect a replacement upper interconnect cable to the
mid-point connector and the upper PCA.
14. Check operation as described in Section 4. If the unit works properly, replace the upper
interconnect cable as described in Procedure 7.4.
15. If the symptoms are unchanged, remove the external upper interconnect cable. Reconnect
the internal upper interconnect cable to the mid-point connector and the upper PCA. Set the
display housing front panel in it’s mounting position and fasten it with the four mounting
screws removed in step 4. Trouble shoot the lower interconnect cable starting with step 9.
Troubleshooting the Lower Interconnect Cable
16. Disconnect the lower interconnect cable from the mid-point connector and the lower PCA.
17. External of the frame, connect a replacement lower interconnect cable to the mid-point
connector and the lower PCA.
18. Check operation as described in Section 4. If the unit works properly, replace the lower
interconnect cable as described in Procedure 7.4.
19. If the symptoms are unchanged, remove the external lower interconnect cable. Reconnect
the internal lower interconnect cable to the mid-point connector and the lower PCA. Remove
the upper and lower interconnect cables from the mid-point connector. Connect a
replacement mid-point connector between the two interconnect cables and retest the unit
per Procedure 4.
20. Replace the lower PCA shield, rear cover (Procedure 7.1) and the main column cover. If the
unit still does function correctly, contact Precor Technical Support.
Mid-Point