C942 Treadmillection Five — Troubleshooting ProceduresProcedure 5.1 — Troubleshooting the Keypad and Upper PCA... 5-3Procedure 5.2
C942 TreadmillProcedure 5.1 — Troubleshooting the Keypad and Upper PCAIf the function keys on the electronic console are unresponsive, the problem may
C942 TreadmillTable 5.2. Voltage Test Points (Function Keys Pressed)Place the positive At the electronic The voltmeter shouldvoltmeter lead on... cons
C942 TreadmillProcedure 5.2 — Troubleshooting the Optional Heart Rate SystemNote:The 9.41S and 9.41Si treadmills are not equipped with heart rate as s
C942 TreadmillTHEN... OTHERWISE...Continue with the next step. The Heart Rate system is operatingcorrectly. There is no need to continuewith this
C942 TreadmillProcedure 5.3 — Troubleshooting the Lift SystemSystem DescriptionThe lift system is powered by a 120 Vac lift motor that uses two indepe
C942 Treadmill8. Remove the P2 connector from the lower board. Using an ohmmeter, measure between terminals 1 and 3 of P2, between terminals 1 and 2 o
C942 TreadmillProcedure 5.6 — Troubleshooting the External A.C. Power SourceIt is extremely important that any Precor treadmill be connected to and op
C942 Treadmill2. The circuit breaker correctly feeds a single A.C. outlet but the neutral is common between several A.C. outlets.The common neutral le